B O D INCUBATOR Specification

  • Product Type
  • incubator
  • Voltage
  • 110-230 Volt (v)
  • Material
  • Milld Steel
  • Color
  • Sky Blue And White
  • Temperature Range
  • 5 to 75 Celsius (oC)
  • Door Type
  • Double Layer, glass window facility
  • Control Panel
  • Microprocessor based digital controller
  • Heating System
  • Air circulating heaters
  • Alarm
  • Temperature deviation alarm
  • Shelves
  • Removable stainless steel trays
  • Power Consumption
  • Approx 0.5 kW
  • Cooling System
  • Hermetically sealed compressor
 

B O D INCUBATOR Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID), Cash Advance (CA)
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Australia, Middle East, Central America, Eastern Europe, South America, Western Europe, North America, Africa
  • Main Domestic Market
  • All India
 

About B O D INCUBATOR

B O D INCUBATOR:- 

B.O.D Incubator We offer B.O.D Incubator that are available in different standard sizes and wide temperature range. B O D incubator is mostly used for drying. Antibody & other bacteriological tests. Crystallization & hydroxy steroid incubation studies, paraffin embedding, slide staining and other microbiological tests at constant temperatures. The used categories include chemicals & bio-chemicals. Pollution control & monitoring. Research & development and quality control labs, pharmaceutical laboratories, microbiological & biotechnology labs, college & classrooms.



Advanced Incubation Technology

The BOD Incubator utilizes a state-of-the-art microprocessor controller that ensures stable and accurate temperature regulation. This provides users with confidence in the consistency of incubation environments, essential for biological testing and growth. Its air circulating heater and hermetically sealed compressor guarantee even distribution of temperature across all removable stainless steel trays.


Flexible Usage and Safety

Equipped with a temperature deviation alarm, the BOD Incubator offers enhanced safety by alerting users to any changes outside the set range. The double layer door, featuring a glass window, provides visual access without disturbing the internal atmosphere, making sample observation convenient while maintaining optimal incubation conditions.


Versatile Applications

Designed for a wide range of laboratory processes, the BOD Incubator accommodates research, industrial, and quality control needs. The adjustable temperature range from 5C to 75C allows processes such as microbial culture preparation, sample preservation, and biochemical oxygen demand testing, making it an indispensable piece of equipment for laboratories.

FAQs of B O D INCUBATOR:


Q: How does the BOD Incubator regulate temperature during incubation?

A: The BOD Incubator features a microprocessor-based digital controller and air circulating heaters, supported by a hermetically sealed compressor, which work together to maintain a consistent temperature between 5C and 75C throughout the incubation process.

Q: What safety features are included in the BOD Incubator?

A: Safety is ensured by a temperature deviation alarm, which notifies users of any unexpected fluctuations, and a double-layer door with a glass window that enables specimen observation without disturbing the internal environment.

Q: When should the BOD Incubator be used in laboratory applications?

A: The incubator is ideal for microbial culture incubation, biochemical oxygen demand tests, and other processes requiring precise temperature control and sample integrity, particularly in research, industrial, or quality control laboratories.

Q: Where is the BOD Incubator commonly utilized?

A: This device is widely used in research institutions, industrial laboratories, quality control departments, and universities across India, thanks to its reliable performance and adaptability to varied scientific applications.

Q: What is the process for monitoring samples without disrupting incubation?

A: Samples can be visually monitored through the glass window in the double-layer door, allowing routine checks without opening the incubator and compromising temperature stability.

Q: How does the removable stainless steel tray design benefit users?

A: Removable stainless steel trays offer flexibility and easy sample organization, making it simple to adjust the internal layout based on experiment requirements and to facilitate thorough cleaning and maintenance.

Q: What voltage range can the BOD Incubator operate on?

A: The incubator is designed to function efficiently on electrical supplies between 110 Volt and 230 Volt, ensuring compatibility with standard power sources commonly available in laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Medical College Instruments & Apparatus Category

PULVERIZER

PULVERIZER

Price 124 INR / Unit

Minimum Order Quantity : 1 Unit

Color : Silver

Product Type : Pulverizers

Usage : Industrial

Material : Mild Steel

TABLET DISINTEGRATION UNIT

TABLET DISINTEGRATION UNIT

Price 104 INR / Unit

Minimum Order Quantity : 1 Unit

Color : White

Product Type : Tablet Disintegration Unit

HEATING MANTLE

HEATING MANTLE

Price 104 INR / Unit

Minimum Order Quantity : 1 Unit

Color : Black And White

Product Type : Heating mantle

Usage : Heaters

RABBIT HOLDER

RABBIT HOLDER

Price 1850.0 INR / Unit

Minimum Order Quantity : 1 Unit

Color : Brown

Product Type : Holder

Usage : For Laboratory

Material : Wooden



Back to top