Change Language

Incubator B O D(Bio Chemical Demand)

Incubator B O D(Bio Chemical Demand)

Product Details:

  • Voltage 110-240 Volt (v)
  • Product Type Incubator
  • Material Stainless Steel
  • Usage laboratory
  • Color White And Blue
130 INR/Unit
X

Incubator B O D(Bio Chemical Demand) Price And Quantity

  • 130 INR/Unit
  • 1 Unit
  • Biochemical Oxygen Demand (BOD) testing, Microbiological Incubation
  • Stainless Steel Mirror Finish (Inner)
  • Low power consumption design
  • LED or Fluorescent Lamp
  • Hermetically sealed, low noise
  • 2 to 4 (Adjustable)
  • Provided for mobility
  • Double Door (Outer and Inner Glass)

Incubator B O D(Bio Chemical Demand) Product Specifications

  • laboratory
  • Stainless Steel
  • 110-240 Volt (v)
  • Incubator
  • White And Blue
  • Biochemical Oxygen Demand (BOD) testing, Microbiological Incubation
  • Stainless Steel Mirror Finish (Inner)
  • Low power consumption design
  • LED or Fluorescent Lamp
  • Hermetically sealed, low noise
  • 2 to 4 (Adjustable)
  • Provided for mobility
  • Double Door (Outer and Inner Glass)

Incubator B O D(Bio Chemical Demand) Trade Information

  • Cash in Advance (CID), Cash Advance (CA)
  • 1000 Unit Per Week
  • 1 Week
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • Australia, Middle East, Central America, South America, Western Europe, Asia, Eastern Europe, North America, Africa
  • All India

Product Description

Incubator B.O.D.(Bio Chemical Demand): Designed for low temp. incubation and routine determination of Bio-Chemical oxygen demand (B.O.D) Double wall construction.Inner chamber made of richly anodized aluminum or highly polished stainless steel sheet with self supports for wide range of shelf spacing.Supplied with two/three removable perforated shelves.Exterior made out of thick mild steel sheet duly finished in white stoving enamel paint or pastel mat finish colour combinations.Outer double wall door is provided with magnetic gasket and lock & key arrangement.Inner door made out of clear acrylic sheet allowing inspection of material in the chamber without disturbing the chamber temp. Door operated inner illumination has been provided.The gap between walls of equipment are filled with glass wool for temp. insulation.The cabinet is mounted on castors. Temp. is controlled by a sensitive thermostat from 5^C to 50^C 1^c.For lower temp. working a standard cooling unit with a sealed compressor with protective devices has been provided below the chamber for safe and efficient working.Heating arrangement has been made witin the chamber for higher temp. working.The temp. can be regulated within the range by means of a high precision double action thermo-regulator.Inner air circulating system is provided to achieve uniform temp. in the whole chamber.A control panel is provided with various indicators, on-off switch, L-shaped thermometer.Supplied with cord and plug etc.The equipment is workable on 220V AC 50Hz single phase. Inner Chamber Sizes in mms. Capacity in cft. (a) 610*455*410 (24"*18"*16") 4.00 (b) 825*500*415 (33"*20"*16.5") 6.1 (c) 865*565*565 (33.5"*22.5"*22.5") 10.0 (d) 900*650*575 (36"*26"*23") 12.0

OPTIONAL: (Extra Cost)

(i) Digital temp. controller-cum-indicator.
(ii) Timer 0-24 hours day night cycle.
(iii) Co2/air mixture inlet nozzle.
(iv) Humidity system by spray or injection methods.
(v) Audio Visual alarm.
(vi) Automatic Voltage stabilizer 3KVA.(must)

Reliable BOD Testing and Microbial Incubation

Our Incubator BOD is purpose-built for conducting Biochemical Oxygen Demand (BOD) testing and supporting a wide range of microbiological incubation processes. Its precise temperature control and uniform chamber conditions make it ideal for consistent, reproducible experimental results. Adjustable shelves accommodate various sample sizes and containers, while dual glass doors allow continuous observation without interrupting the environment. This incubator is engineered to deliver reliability in routine laboratory work.


Quality Construction for Laboratory Safety and Durability

Constructed using high-grade stainless steel, the Incubator BOD features a mirror-finished inner chamber to facilitate easy cleaning and corrosion resistance. The thoughtfully designed exterior in white and blue ensures compatibility with modern laboratories, and integrated casters support safe, easy movement. The hermetically sealed low-noise compressor keeps operational sounds minimal while reducing power consumption, resulting in a more pleasant work environment for lab technicians.

FAQs of Incubator B O D(Bio Chemical Demand):


Q: How is the Incubator BOD used in a laboratory setting?

A: The Incubator BOD is used to maintain controlled temperature conditions for Biochemical Oxygen Demand (BOD) tests and microbiological incubations. Users place their samples on the adjustable shelves, set the temperature as required, and utilize the dual glass doors to monitor experiments without disturbing the internal environment.

Q: What makes this incubator suitable for BOD testing?

A: This incubator offers precise temperature regulation and stable internal conditions, both critical for accurate BOD testing. Its stainless steel inner chamber provides a non-reactive surface, ensuring reliability and preventing contamination during sensitive biochemical assays.

Q: Where is this incubator typically used?

A: It is widely used in research institutions, academic laboratories, water treatment facilities, and pharmaceutical labs across India, wherever BOD analysis and microbiology experiments are conducted.

Q: What benefits does the stainless steel construction provide?

A: Stainless steel construction ensures corrosion resistance, easy cleaning, durability, and a hygienic environment for sensitive experiments, making it an excellent choice for rigorous laboratory use.

Q: When should the shelves be adjusted or reconfigured?

A: The adjustable shelves can be moved or reconfigured based on the volume, size, and number of samples being incubated, allowing flexible and efficient use of the chamber space.

Q: How does the lighting system benefit my incubation process?

A: The integrated LED or fluorescent lamp illuminates the interior, making it easy to observe samples and monitor growth patterns without opening the doors, reducing temperature fluctuations and potential contamination.

Q: What are the advantages of the hermetically sealed, low-noise compressor?

A: The sealed compressor ensures consistent cooling, low energy usage, and ultra-quiet operation, contributing to overall energy efficiency and a more comfortable laboratory environment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Scientific Product' category



Back to top