Change Language
Study Of Microwave Component
Study Of Microwave Component

Study Of Microwave Component

Price 42500.0 INR/ Unit

MOQ : 1 Unit

Study Of Microwave Component Specification

  • Temperature Resistance
  • Up to 70°C
  • Accuracy
  • High Measurement Accuracy
  • Display Type
  • Digital Display
  • Power Supply
  • AC Mains
  • Shape
  • Rectangular
  • Features
  • Rugged Design, Accurate Measurement, Easy Interface
  • Control Type
  • Manual and Electronic Controls
  • Usage
  • Laboratory
  • Type
  • Microwave Component
  • Dimension (L*W*H)
  • Standard Laboratory Size
  • Product Type
  • Microwave Component
  • Equipment Type
  • Laboratory Testing Equipment
  • Equipment Materials
  • High-Quality Metal and Electronics
  • Color
  • Silver And Black
  • Power
  • 50 W (typical)
  • Voltage
  • 110-220 Volt (v)
  • Material
  • Metal
  • Application
  • Study and Analysis of Microwave Components in Laboratory
  • Weight
  • Approx. 8-10 kg
  • Microwave Frequency Range
  • Standard Laboratory Frequency Range (e.g., 1 GHz to 12 GHz)
  • Operating Environment
  • Indoor, Laboratory Controlled
  • Connector Type
  • SMA/N-type Connectors
  • Test Functions
  • Waveguide Analysis, Attenuation, Impedance Matching
  • Mounting
  • Tabletop
  • Included Accessories
  • Connecting Cables, User Manual
  • Compliance
  • Meets Standard Laboratory Safety Norms
 

Study Of Microwave Component Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Western Europe, Asia, Australia, North America, Eastern Europe, Middle East, Central America, South America, Africa
  • Main Domestic Market
  • All India
 

About Study Of Microwave Component

Study of  Microwave Component (Magic Tee, Directional Coupler, Isolator, Circulator)
Experiments:
1.
 To study Magic Tee, Directional Coupler, Isolators & Circulators.
2. To measure charcteristics of detector diode.
3. To study attenuation measurements.
4. To study the return loss measurements.

Component  Name

Qty.

Klystron power supply

1

Klystron Tube

1

Frequency Meter

1

Fixed Attenuator 3,6,10db

3

Detector Mount

1

Slotted Section

1

VSWR Meter Solid State

1

S S Tunner

1

Cooling Fan

1

MHD Coupler 3,10,20db

3

E-Plane Tee

1

Klystron Mount

1

Isolator

1

Variable Attenuator

1

Magic Tee

1

Movable Short

1

Tunable Probe

1

Stands

4

BNC Cable

1

Matched termination

1

Cirulator

1

H-Plane Tee

1




Versatile Laboratory-Grade Microwave Testing

This microwave component analyzer is meticulously designed for laboratory applications such as waveguide analysis, attenuation, and impedance matching, vital for research, education, and industrial testing. Its digital display and ergonomic interface ensure easy data interpretation, while manual and electronic controls provide flexibility for students and professionals alike. Standard SMA/N-type connectors and comprehensive accessories facilitate seamless integration and setup in any controlled lab environment.


Precision, Durability, and Safety Combined

Constructed with high-quality metals and electronics, this equipment promises reliability under rigorous laboratory conditions. With a temperature resistance up to 70C, a rugged rectangular design, and compliance with safety norms, users can depend on consistent, safe operation. Its standard lab dimensions, approximate 8-10 kg weight, and 50 W power efficiency make it a practical choice for various laboratory setups in India and beyond.

FAQs of Study Of Microwave Component:


Q: How do I use the Study Of Microwave Component for waveguide analysis in my laboratory?

A: To conduct waveguide analysis, connect your waveguide sample to the equipment using the included SMA/N-type connectors and cables. Use the manual or electronic controls to select your test function, monitor readings via the digital display, and refer to the provided user manual for step-by-step procedures. The system is optimized for straightforward setup and operation in a controlled laboratory environment.

Q: What are the main benefits of using this microwave testing equipment in a laboratory setting?

A: The equipment offers high measurement accuracy, reliable digital display for easy interpretation, and robust construction for durability. Its versatile test functionscovering waveguide analysis, attenuation, and impedance matchingsuit a variety of microwave experiments and research, making it valuable for both educational and professional laboratory applications.

Q: When should I consider this component for my lab studies or research projects?

A: This microwave component is ideal for use when your studies or research require precise measurement and analysis within the 1 GHz to 12 GHz frequency range. Its particularly beneficial for experiments involving waveguides, attenuation, and impedance matching, or when safety, accuracy, and ease of use are a priority.

Q: Where is this equipment best installed and operated?

A: The device is engineered for indoor, laboratory-controlled environments and should be mounted on a tabletop. Its suitable for university labs, R&D centers, and industrial testing facilities where controlled conditions can be ensured for reliable measurements.

Q: What is the process for setting up the equipment upon delivery?

A: On receiving the equipment, unbox and place it on a stable laboratory table. Connect the power supply to the AC mains (110-220V), attach SMA/N-type connectors and the provided cables, and follow the user manual for calibration and initial setup. The digital interface and controls make it easy to begin measurements quickly.

Q: How does this equipment ensure accurate and safe measurement results?

A: The device incorporates high-precision electronics, a reliable digital display, and conforms to standard laboratory safety norms. Its rugged, metal construction protects internal components, while the robust interface and control options minimize user error, ensuring repeatable and accurate results.

Q: What are the included accessories, and how do they enhance usage?

A: The package includes connecting cables and a comprehensive user manual. These accessories support easy setup and proper operation, ensuring users can efficiently connect their samples and understand the testing procedures, which helps maximize the equipments potential.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Engineering Electronics College Products Category

Universal Vibration Apparatus

Universal Vibration Apparatus

Price 73950.0 INR / Unit

Minimum Order Quantity : 1 Unit

Voltage : 230 Volt (v)

Color : Green And White

Product Type : Vibration Apparatus

Material : Mild steel

Static and Dynamic Balancing App

Static and Dynamic Balancing App

Price 47500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Voltage : 220 Volt (v)

Color : Silver And Sky Blue

Product Type : Dynamic Balancing

Material : Stainless Steel

Motorized Gyroscope Apparatus

Motorized Gyroscope Apparatus

Price 35000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Voltage : 220 Volt (v)

Color : White And Blue

Product Type : Gyroscope Apparatus

Material : Mild Steel

Whirling of Shaft Demonstrator

Whirling of Shaft Demonstrator

Price 34500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Voltage : 220 Volt (v)

Color : White And Blue

Product Type : Demonstrator

Material : Stainless steel



Back to top